Power Generation

Power Generation Product Finder

Application Group Types

The followings are an explanation of the various application group types.
Standby power

Standby power (3D)  

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

Uptime compliant

mtu  Power Generation

variable

≤ 85%

no

500 h  

Tier I & Tier II

ISO 8528-1 (ESP)

variable

≤ 70%

not specified

200 h

not specified

Prime power for stationary emergency (3E)

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

Uptime compliant

mtu  Power Generation

variable

≤ 85%

yes

500 h  

Tier I & Tier II

ISO 8528-1 (ESP)

variable

≤ 70%

not specified

200 h

not specified

Data center continuous power (3F)

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

Uptime compliant

mtu  Power Generation

continuous  

≤ 100%

yes

unlimited

Tier I - Tier IV

ISO 8528-1 (DCP)

continuous or variable

≤ 100%

not specified

unlimited

not specified

Continuous/Prime/Grid stability power

Continuous power + CHP (3A)

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

mtu  Power Generation

constant

≤ 100%

Gas: no, Diesel: yes

unlimited

ISO 8528-1 (ESP)

constant

≤ 100%

not specified

unlimited

Prime power (3B)

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

mtu  Power Generation

variable

≤ 75%

yes

unlimited

ISO 8528-1 (PRP)

variable

≤ 70%

yes

unlimited

Grid stability power (3G)

Load

Load factor

10% overload (ICXN)

Max. operating hours (per year)

mtu  Power Generation

continuous

≤ 100%

Gas: no, Diesel: yes

1000 h; 500 h with 100% load w/o interruption

ISO 8528-1 (LTP)

continuous

≤ 100%

not specified

500 h

Diesel Generator Sets

Product results are displayed by power range from lowest to highest. To see fewer results, select one or more filters.
Power
Range(kVA)
  • Standby power
  • Prime power for stationary emergency
  • Data center continuous power
  • Prime power
  • Grid stability power
  • Continuous power
  • Fuel consumption optimized
  • NEA (ORDE) optimized
  • NOx emission optimized
  • Exhaust-optimized
  • Exhaust emission EU 97/68 EC Stage II compliant
  • EPA Tier 2 optimized
  • Tier 2 compliant
  • 40CFRP60
  • Series 1600
  • Series 2000
  • Series 4000
  • Clear filter
  • 12V1600 DS1000
  • 12V1600 DS650
  • 12V1600 DS715
  • 12V1600 DS825
  • 12V1600 DS880
  • 12V2000 DS1000
  • 12V2000 DS825
  • 12V4000 DS1650
  • 12V4000 DS1750
  • 12V4000 DS2000
  • 12V4000 DS2250
  • 16V2000 DS1000
  • 16V2000 DS1100
  • 16V2000 DS1250
  • 16V4000 DS2250
  • 16V4000 DS2500
  • 16V4000 DS2750
  • 16V4000DS2750
  • 18V2000 DS1400
  • 20V4000 DS3600
  • 20V4000 DS4000
  • 20V4000 DS2750
  • 20V4000 DS3100
  • 20V4000 DS3300
  • 20V4000 DS3600
  • 20V4000 DS4000
  • Clear filter
  • Air charge-air cooling
  • Water charge-air cooling
  • Water-to-Air charge cooling

Info

See the explanation section at the top of the page.

Europe, Africa, Asia and Australia
590 kVA Prime Power NOx emission optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Prime power for stationary emergency NOx emission optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Data center continuous power NOx emission optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS650 Air charge-air cooling
590 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS650 Air charge-air cooling
650 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS650 Air charge-air cooling
650 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS650 Air charge-air cooling
650 kVA Prime Power NOx emission optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Prime power for stationary emergency NOx emission optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Data center continuous power NOx emission optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS715 Air charge-air cooling
650 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS715 Air charge-air cooling
715 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS715 Air charge-air cooling
715 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS715 Air charge-air cooling
750 kVA Continuous power Fuel consumption optimized Series 2000 12V2000 DS1000 Air charge-air cooling
750 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS825 Air charge-air cooling
750 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
750 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
800 kVA Prime power Fuel consumption optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power NOx emission optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power NEA (ORDE) optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power Tier 2 compliant Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Continuous power Fuel consumption optimized Series 2000 16V2000 DS1250 Air charge-air cooling
800 kVA Continuous power Fuel consumption optimized Series 2000 16V2000 DS1250 Water charge-air cooling
800 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power for stationary emergency NOx emission optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 12V2000 DS1000 Air charge-air cooling
800 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS880 Air charge-air cooling
800 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
800 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
825 kVA Standby power NOx emission optimized Series 2000 12V2000 DS825 Air charge-air cooling
825 kVA Standby power NEA (ORDE) optimized Series 2000 12V2000 DS825 Air charge-air cooling
825 kVA Standby power Tier 2 compliant Series 2000 12V2000 DS825 Air charge-air cooling
825 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS825 Air charge-air cooling
825 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS825 Air charge-air cooling
825 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS825 Air charge-air cooling
825 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
825 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
825 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS825 Water-to-Air charge cooling
880 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS880 Air charge-air cooling
880 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS880 Air charge-air cooling
880 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS880 Air charge-air cooling
880 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
880 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
880 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS880 Water-to-Air charge cooling
900 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Air charge-air cooling
900 kVA Prime Power Fuel consumption optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Prime Power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Prime Power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Prime power for stationary emergency Fuel consumption optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Prime power for stationary emergency EPA Tier 2 optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Data center continuous power Fuel consumption optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Data center continuous power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
900 kVA Data center continuous power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
910 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power for stationary emergency NOx emission optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 16V2000 DS1000 Air charge-air cooling
910 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power for stationary emergency NOx emission optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 16V2000 DS1000 Water charge-air cooling
910 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 16V2000 DS1000 Water charge-air cooling
1000 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power for stationary emergency NOx emission optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power for stationary emergency NOx emission optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Data center continuous power Fuel consumption optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Data center continuous power NOx emission optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Data center continuous power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Data center continuous power Tier 2 compliant Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Data center continuous power Fuel consumption optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Data center continuous power NOx emission optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Data center continuous power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Data center continuous power Tier 2 compliant Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Grid stability power Fuel consumption optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Grid stability power NOx emission optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Grid stability power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Grid stability power Tier 2 compliant Series 2000 16V2000 DS1100 Air charge-air cooling
1000 kVA Grid stability power Fuel consumption optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Grid stability power NOx emission optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Grid stability power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Grid stability power Tier 2 compliant Series 2000 16V2000 DS1100 Water charge-air cooling
1000 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS1000 Air charge-air cooling
1000 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Air charge-air cooling
1000 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Air charge-air cooling
1000 kVA Standby power Fuel consumption optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
1000 kVA Standby power NEA (ORDE) optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
1000 kVA Standby power EPA Tier 2 optimized Series 1600 12V1600 DS1000 Water-to-Air charge cooling
1010 kVA Standby power Fuel consumption optimized Series 2000 12V2000 DS1000 Air charge-air cooling
1010 kVA Continuous power Fuel consumption optimized Series 2000 18V2000 DS1400 Air charge-air cooling
1010 kVA Continuous power Fuel consumption optimized Series 2000 18V2000 DS1400 Water charge-air cooling
1100 kVA Standby power NOx emission optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1100 kVA Standby power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Air charge-air cooling
1100 kVA Standby power Tier 2 compliant Series 2000 16V2000 DS1100 Air charge-air cooling
1100 kVA Standby power NOx emission optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1100 kVA Standby power NEA (ORDE) optimized Series 2000 16V2000 DS1100 Water charge-air cooling
1100 kVA Standby power Tier 2 compliant Series 2000 16V2000 DS1100 Water charge-air cooling
1135 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power Fuel consumption optimized Series 2000 16V2000 DS1250 Water charge-air cooling
1135 kVA Prime power NOx emission optimized Series 2000 16V2000 DS1250 Water charge-air cooling
1135 kVA Prime power NEA (ORDE) optimized Series 2000 16V2000 DS1250 Water charge-air cooling
1135 kVA Prime power Tier 2 compliant Series 2000 16V2000 DS1250 Water charge-air cooling
1135 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power for stationary emergency NOx emission optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power for stationary emergency NEA (ORDE) optimized Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power for stationary emergency Tier 2 compliant Series 2000 16V2000 DS1250 Air charge-air cooling
1135 kVA Prime power for stationary emergency Fuel consumption optimized Series 2000 16V2000 DS1250 Water charge-air cooling
1135 kVA